Triatek

Technical Support | 770-242-1922

  • Home
  • About Triatek
    • Overview
    • Why Choose Triatek?
  • Products
    • Stable Vortex® II Fume Hood
    • Stable Vortex® Fume Hood Conversion Kit
    • Fume Hood Controllers
      • HMS-1655 Fume Hood Controller
    • Room Pressure Controllers
      • FMS-2000C Critical Environment Controller
      • FMS-2000M Critical Environment Monitor
      • FMS-1655 Room Pressure Controller
    • LITE Monitors
      • HMS-1655 LITE Fume Hood Monitor
    • Remote Displays
      • HMS-1655R Remote Display
    • Central Monitoring Stations
      • CMS-1655 Central Monitoring Station
    • Actuators
      • ACT-FA-8002 Fast-Acting Actuator
      • ACT-FA-9001 Smart Actuator
    • Network Gateways
    • Sensors
      • Digital Sidewall Sensor
      • SWD Door Switch Sensors
      • SPS-50 Sash Position Sensor
      • T-STAT Room Temperature Sensor
      • T-STAT Room Temperature and Humidity Sensor
      • Zone Presence Sensor
    • Lighting Products
      • LP-3500 Lighting Control Panel
    • Venturi Valves
      • Venturi Valve Overview
      • Stainless Steel Venturi Valve
      • Universal Valve Module (UVM)
      • Low Pressure Constant Volume Venturi Valve
      • Low Pressure Partially Closed Venturi Valve
      • Low Pressure Shut-Off Venturi Valve
      • Medium Pressure Constant Volume Venturi Valve
      • Medium Pressure Partially Closed Venturi Valve
      • Medium Pressure Shut-Off Venturi Valve
      • Venturi Valve Upgrade Kit
      • Venturi Valve Drawband Clamp
  • Integrated Solutions
    • Laboratory Solutions
    • Healthcare Solutions
  • How to Buy
    • United States
    • International
  • News & Media
  • Contact
  • Resource Library
    • Data Sheets, Manuals, and PIC Statements
    • Brochures and Case Studies
  • Case Studies
    • Laboratory
      • Georgia Tech Carbon Neutral Energy Solutions Laboratory
      • University of New Mexico – Castetter Hall
    • Healthcare
      • Women & Children’s Hospital of Buffalo
    • Municipal
      • Northeast Ohio Correctional Center
      • North Louisiana Forensics Science Center
    • Lighting
      • Bank of America Carolina Panthers Stadium
  • Technical Support
    • Phone and On-Site Support
    • FAQ
    • FMS Sensor Calibration
    • Installation Tips
      • Venturi Valves
      • FMS / HMS Products
      • Sensors
    • Calculators
      • Area Conversion
      • Length Distance Conversion
      • Pressure Conversion
      • Weight Mass Conversion
  • Training
    • Sales Training
    • Technical Training
  • USP-800
You are here: Home / News / Healthcare HVAC Systems and Disease Mitigation 

Healthcare HVAC Systems and Disease Mitigation 

Downloadable Version

Isolation Room Preparedness for COVID-19 Patients

According to the CDC and ASHRAE, hospital HVAC systems play a critical role in mitigating the spread of diseases like COVID-19, MERS, SARS, and tuberculosis. When an infected person coughs or sneezes, respiratory droplets can travel through the air and be inhaled by people nearby.  Room pressurization, air change rates, humidity, and temperature all play an integral role in mitigating airborne contaminants to provide a healing space for patients while protecting healthcare providers.

It is recommended by the ANSI/ASHRAE/ASHE Standard 170-2017  and the CDC to place patients with a suspected or known COVID-19 diagnoses in airborne isolation infection room (AIIR). AIIRs are negative pressure single-patient rooms with a minimum of 6 air changes per hour (12 are recommended for new construction).

Triatek negative pressure room

AIIRs constantly provide clean air to patients and help protect staff from infection. AIIRs contain, dilute, and exhaust contaminated air through a high-efficiency particulate air (HEPA) filter, and then vent it outdoors.

The negative pressure prevents contaminated droplets from traveling to other areas of the hospital when the doors are opened. Room doors should be kept closed except when personnel are entering and exiting. Entry and exits should be minimized as air currents from personnel traffic can disrupt proper airflow, so AIIR HVAC equipment must be fast-acting, adjusting immediately to changing conditions. Facilities should monitor and document AIIR negative pressure function, and there should be a constant visual indication from the room pressure controller or monitor.

Airborne Infection Isolation Room (AIIR) Checklist

Utilize this checklist to help ensure your AIIRs are ready to receive patients with suspected or confirmed Coronavirus Disease 2019 (COVID-19). For more details, refer to the ANSI/ASHRAE/ASHE Standard 170-2017 Ventilation of Health Care Facilities.

  • Verify the room sensors are calibrated and working properly
  • Verify room controllers and monitors are working and communicating with airflow valves
  • Verify the room is operating at a negative pressure relative to surrounding areas
  • Verify room pressure is being properly documented
  • Verify correct air changes per hour are taking place per CDC/ASHRAE standards
  • Verify temperature and humidity ranges are in place per CDC/ASHRAE standards
  • Verify room air is being exhausted directly outside through a HEPA filter
  • Verify doors are being kept closed except during healthcare personnel entry/exit
  • Confirm patient rooms are visible on your BAS, for prompt notification of any issues
  • Consider updating older VAV boxes to a fast-acting Venturi air valve or measured airflow valve
  • Plan for an influx of patients and how to address isolation requirements in your facility

Airborne Infection Isolation Room (AIIR) Checklist

ASHRAE Resources

ASHRAE COVID-19 Resources
ASHRAE has developed resource center with guidance dedicated to addressing concerns around COVID-19 with respect to the operation and maintenance of HVAC systems.

ANSI/ASHRAE/ASHE Standard 170-2017 Ventilation of Health Care Facilities
Standard 170-2017 is the foremost guideline for ventilation requirements in healthcare facilities.

ASHRAE Position Document on Airborne Infectious Diseases
This position paper reinforces Standard 170-2017 and recommends facilities go above and beyond published standards.

Mitigating Airborne Infection Transmission with HVAC Systems Article
This article coalesces several research articles from previous ASHRAE Journal editions on AIIRs.

Removal of Airborne Contamination in Airborne Infectious Isolation Rooms
The article features a study that evaluated the ventilation performance of three strategies for HVAC control for airborne infectious diseases.

CDC Resources

COVID-19 Infection Prevention and Control Recommendations
This resource provides information for infection prevention and control recommendations, including engineering controls for patients with suspected or confirmed Coronavirus Disease 2019 (COVID-19).

Airborne Contaminant Removal
This resource provides information on required duration and air changes per hour for effective airborne-contaminant removal.

Need Help?

Triatek is committed to ensuring airborne isolation rooms are ready to receive COVID-19 patients. Contact us if your facility needs help to meet ASHRAE and CDC requirements so your healthcare team can provide best-in-class care to those who need it most. Reach out to your local Triatek rep or contact us directly.

Get a product quote: sales@triatek.com
General inquiry: caroline.moore@jci.com
Call us: 770-242-1922

Filed Under: News

Sign Up For News

  • This field is for validation purposes and should be left unchanged.

Recent News and Press Releases

  • 2022 I­²SL Conference
  • Healthcare HVAC Systems and Disease Mitigation 
  • AHR Expo 2020
  • I²SL 2019 Annual Conference
  • ASHE PDC Summit 2019

Case Studies

Georgia Tech Carbon Neutral Energy Solutions LaboratoryGeorgia Tech Carbon Neutral Energy Solutions Laboratory

Triatek’s integrated laboratory solutions are part of the award winning, energy-efficient, and minimalist design that reduces electricity loads, maximizes the use of renewable energy, and capitalizes on passive energy technologies.

Read More Details »

Latest Tweets

Triatek is migrating our tweets to the @johnsoncontrols account, so be sure to give them a follow to catch all the latest Triatek updates! Stop by #Booth3833 during the #AHRexpo next week in Orlando to demo our NEW FMS-2000 Critical Environment Controller. pic.twitter.com/HpxGC34zeP

About 3 years ago from Triatek Sales's Twitter via Twitter Web App · reply · retweet · favorite

We'll be exhibiting with @johnsoncontrols at the @ASHEAHA PDC Summit in Phoenix, AZ! Stop by Booth 818 and lets discuss how to create a safe, efficient, and sustainable #healthcare built environment. Check out our blog post to learn more: triatek.com/news/ashe-pdc-… #PDCsummit pic.twitter.com/IitWyzyuoM

About 4 years ago from Triatek Sales's Twitter via Twitter Web Client · reply · retweet · favorite

Join us at 1:00 in the JCI Presentation Theater for a Top Talk on the .@ahrexpo Innovation Award Finalist - The EcoAir Valve! If you are interested in critical environments and energy efficiency, this presentation is for you! #AHRexpo #ahr2019 #labs #healthcare pic.twitter.com/ZU60xOAOiB

About 4 years ago from Triatek Sales's Twitter via Twitter for iPhone · reply · retweet · favorite

Follow @TriatekSales

About Triatek

Since 1985 Triatek has been on the forefront of designing and manufacturing innovative airflow solutions for critical environments. Headquartered near Atlanta, Georgia, Triatek provides end-to-end solutions for healthcare facilities, laboratories, and municipal facilities around the world. Our … Learn more »

Contact Triatek

social-media-icons-linked-insocial-media-icons-twitter4366 Shackleford Rd
Suite B
Norcross, GA 30093

Technical Support | 770-242-1922
Sales | sales@triatek.com
Service | service@triatek.com

 

©2023 Triatek. All Rights Reserved.

Privacy | Site Map | Contact

Website by Sangfroid Web, LLC

This site uses cookies to offer you a better browsing experience. By continue to navigate through this site or by clicking Approve, you consent to the use of cookies on your device as described in our privacy notice.

Accept